GA90
90 kVA diesel ground power unit with dual 400 Hz and optional 28 VDC output for narrow-body and regional aircraft servicing.
The Guinault GA90 is a mobile, diesel-engine-driven ground power unit delivering 90 kVA of regulated 400 Hz / 115–200 V three-phase power, the standard electrical supply format required by commercial transport aircraft for avionics, cabin systems, and pre-flight checkout. An optional simultaneous 28 VDC output (800 A continuous / 2,500 A peak) covers aircraft battery charging and DC-bus loads on the same unit without a secondary cart. The GA90 sits at the entry point of Guinault's mainline GA range and is suited to single-aisle aircraft such as the A320 family and Boeing 737, as well as regional jets and turboprops. It is the go-to choice for airports with high aircraft-per-gate throughput where a smaller footprint GPU matters — particularly at stands with constrained apron space or where towing radius is limited. Engine options span Deutz and Cummins, both available in emission tiers up to Stage 5 / Tier 4 Final, ensuring compliance with current airside emission regulations in Europe and North America. The alternator is Guinault's own brushless 28-pole design, directly coupled and running at 1,714 RPM for low harmonic distortion. Built-in WiFi, GSM, and GPS telematics allow fleet managers to monitor run-hours, fuel consumption, fault codes, and location remotely — a meaningful operational gain for large mixed fleets. The unit is rated for operation from −30 °C to +50 °C, covering both northern-Europe winter starts and high-ambient-temperature ramp environments including the Gulf region, where ground temperatures routinely exceed 40 °C. Available as a towable trailer or self-propelled chassis.
Technical specifications.
| Engine options | Deutz or Cummins (Stage 5 / Tier 4F available) |
| Alternator | Guinault brushless 28-pole, 1,714 RPM |
| Telematics | WiFi, GSM, GPS |
| Power output | 90 kVA |
| Output voltage | 115/200 V, 3-phase with neutral |
| Output frequency | 400 Hz |
| Optional DC output | 800 A rated / 2,500 A peak 28 VDC |
| Power factor | 0.8–1.0 |
| Operating temperature | −30 °C to +50 °C |
| Humidity | Up to 95% RH |
| Dimensions (L×W×H) | 3,300 × 1,880 × 1,790 mm |
| Operating weight | 2,200 kg |
Use cases.
- ›Main-line narrow-body ground power at busy hub stands (A320, B737)
- ›Regional jet and turboprop servicing at smaller airports
- ›APU-OFF programmes where GPU replaces onboard auxiliary power on the gate
- ›Remote or mobile operations requiring self-propelled or towable GPU flexibility
- ›High-ambient-temperature ramp environments including GCC airports