Daikin Trailblazer AGZ-F / EWYQ Air-Cooled Scroll Chiller
Daikin logo
Supplier
Daikin
HVAC & Climate Systems

Daikin Trailblazer AGZ-F / EWYQ Air-Cooled Scroll Chiller

Compact R-32 air-cooled scroll chiller from 30 to 230 tons, rated to 52°C ambient with the optional high-ambient package.

Specs verified against manufacturer documentation
Cooling capacity range (AGZ-F)
30–230 tons
Power input range
100–810 kW
IPLV efficiency
Up to 20.95 EER
Refrigerant
R-32 (GWP=675, low-GWP class)
Pricing
Request a quote for current pricing, lead time and delivery to your airport.

The Daikin Trailblazer AGZ-F is an air-cooled scroll chiller purpose-built around low-GWP R-32 refrigerant, covering 30 to 230 tons in a modular platform designed to minimise mechanical-room footprint. Compared to its predecessor (AGZ-E), the AGZ-F delivers a claimed 33% reduction in spatial footprint, 10% weight reduction, and 15% improvement in integrated part-load efficiency — changes that matter in constrained plant rooms or rooftop plantdecks where structural and spatial limits govern equipment selection. R-32's higher volumetric cooling capacity also reduces refrigerant charge by up to 88% versus the previous generation, directly lowering leak-risk exposure and simplifying F-gas compliance documentation.

Standard units operate in ambient temperatures from 0°C to 41°C (32°F to 105°F). For GCC deployments — where summer ambient temperatures at ground level routinely exceed 45°C and can reach 52°C on exposed rooftop plantdecks — Daikin offers an optional high-ambient package extending the operating envelope to 52°C (125°F). This makes the AGZ-F genuinely deployable in Dubai, Riyadh, Doha, and Abu Dhabi summers without de-rating or operational restriction.

The EWYQ heat pump variant adds reversible operation, providing electricity-driven heating at up to three times the energy input — useful in facilities requiring year-round simultaneous heating and cooling, or in markets where gas infrastructure is being phased out. Both variants use MicroTech III controls with AHRI certification and seismic compliance, and accept BAS integration via standard protocols. The scroll compressor's inherent low vibration and sound profile suits rooftop installations above occupied spaces such as terminal concourses or hotel airside accommodation blocks.

From the manufacturer’s documentation

Technical specifications.

Performance & capability
Cooling capacity range (AGZ-F)30–230 tons
IPLV efficiencyUp to 20.95 EER
RefrigerantR-32 (GWP=675, low-GWP class)
Standard ambient operating range0°C to 41°C (32°F to 105°F)
High-ambient option operating rangeUp to 52°C (125°F)
Compressor typeScroll (air-cooled)
Footprint reduction vs previous gen33 %
Refrigerant charge reduction vs previous genUp to 88 %
Heat pump efficiency (EWYQ)Up to 300 % (COP ~3.0)
CertificationsAHRI, ASHRAE 90.1-2016, seismic certified
Interfaces & integration
Power input range100–810 kW
Best for

Use cases.

  • Rooftop or exposed plantdeck cooling in GCC airports requiring operation above 45°C ambient (high-ambient package required)
  • Small-to-medium terminal buildings, airside hotels, and cargo facilities from 30 to 230 tons
  • Facilities with strict refrigerant-charge or F-gas audit requirements benefiting from R-32's reduced charge volume
  • Applications where heat pump reversibility (EWYQ) enables year-round heating and cooling from a single air-cooled unit
  • Retrofit replacements in constrained plantrooms where the AGZ-F's reduced footprint and weight simplify structural compliance
Daikin Trailblazer AGZ-F / EWYQ Air-Cooled Scroll Chiller · Aviation Souk