TCA Oil-Free Magnetic-Bearing Air-Cooled Centrifugal Chiller
Oil-free air-cooled magnetic-bearing centrifugal chiller rated 300–850 tons, delivering up to 3 MW of cooling with Rapid Restart for mission-critical environments.
The TCA is Trane's highest-capacity oil-free air-cooled chiller, using a magnetic-bearing centrifugal compressor that operates without contact between rotating surfaces and therefore without lubricating oil. Rated from 300–850 tons (up to 3 MW) it covers the upper band of air-cooled capacity where competing screw-based units reach their efficiency or size limits. Operating refrigerants are low-GWP R-515B or R-1234ze (GWP <1), both of which are under active specification in refrigerant-regulation-driven upgrades across the Middle East and Europe.
The elimination of oil removes degradation in heat-exchanger efficiency over time (oil fouling of evaporator tubes) and removes the oil-management maintenance programme entirely. The magnetic-bearing compressor can start and stop without a warm-up period, enabling rapid response to load changes and direct compatibility with Rapid Restart — the chiller recovers full capacity within seconds of a power event. This feature is fundamental to airport data-centre and ATC backup-cooling specifications where cooling loss during a UPS switchover is not acceptable.
Advanced Intelligent Controls for Data Centers is the standard controller on the TCA, rather than the Symbio 800 used on Trane's comfort-cooling range — this is a meaningful product-selection signal indicating the TCA is positioned as mission-critical infrastructure, not commercial comfort cooling. The air-cooled format eliminates water-treatment, cooling-tower maintenance, and condenser-water-treatment chemical programmes, reducing total lifecycle operational complexity versus an equivalent water-cooled centrifugal plant in a sandy, high-ambient GCC environment.
Technical specifications.
| Capacity range | 300–850 tons (up to 3 MW) |
| Model | TCA |
| Compressor type | Oil-free magnetic-bearing centrifugal |
| Refrigerant options | R-515B or R-1234ze (GWP <1) |
| Ambient operating range | -20 to +130 °F (-29 to +54 °C) |
| Chilled-water delivery range | 60–86 °F (15–30 °C) |
| Rapid Restart | Standard feature |
| Equipment controller | Advanced Intelligent Controls for Data Centers |
Use cases.
- ›Airport data-centre and operations-centre primary cooling plant
- ›Large terminal comfort cooling where water-cooled infrastructure is absent
- ›Mission-critical cooling requiring near-zero downtime on power interruption
- ›High-capacity GCC ramp-facility cooling in extreme ambient conditions
- ›Sustainable replacement for legacy air-cooled screw or centrifugal plant with HFC refrigerants