YORK CYK Water-to-Water Compound Centrifugal Chiller / Heat Pump
Johnson Controls | YORK logo
Supplier
Johnson Controls | YORK
HVAC & Climate Systems

YORK CYK Water-to-Water Compound Centrifugal Chiller / Heat Pump

Compound centrifugal chiller-heat pump producing simultaneous 42°F chilled water and up to 180°F hot water from a single water-cooled system.

Specs verified against manufacturer documentation
Cooling Capacity Range
300–2,500 TR
Cooling Capacity Range (kW)
1,050–8,800 kW
Heating Capacity Range
10,000–40,000 MBH
Heating Capacity Range (kW)
2,900–11,700 kW
Pricing
Request a quote for current pricing, lead time and delivery to your airport.

The YORK CYK is a water-to-water compound centrifugal unit that runs two motor-driven centrifugal compressors in a compound arrangement to deliver both high-grade heating and full-load chilling simultaneously. The cooling side covers 300 to 2,500 TR (1,050–8,800 kW); the heating side delivers 10,000 to 40,000 MBH (2,900–11,700 kW). Critically, it can output chilled water at 42°F (5.6°C) and hot water at up to 180°F (82°C) at the same time — a thermal versatility unavailable from any single-stage machine.

As a heat pump the CYK captures condenser rejection heat that a conventional chiller discards and upgrades it to process-usable temperatures. Johnson Controls cites three-to-five times greater efficiency than a traditional boiler-plus-chiller combination, and up to 50% reduction in water and operational costs for facilities currently running parallel boiler and chiller infrastructure. Turndown reaches 25% of design capacity through variable-speed drive and compressor VI control.

Optional ultra-low-GWP refrigerants R-1234ze and R-515B are available. A patented double-bundle condenser option enables efficient part-load heat management. For airport operators managing large passenger terminal complexes where simultaneous heating of retail and catering zones and cooling of concourses is a year-round requirement, the CYK eliminates the capital and maintenance overhead of separate boiler plant.

From the manufacturer’s documentation

Technical specifications.

Performance & capability
Cooling Capacity Range300–2,500 TR
Cooling Capacity Range (kW)1,050–8,800 kW
Heating Capacity Range10,000–40,000 MBH
Heating Capacity Range (kW)2,900–11,700 kW
Minimum Turndown25%
Efficiency vs Boiler + Chiller3–5x more efficient
Refrigerant OptionsR-1234ze / R-515B (optional low-GWP)
Compressor TypeTwo electric motor-driven centrifugal compressors
Power & environment
Chilled-Water Temperature42°F / 5.6°C
Hot-Water Temperature (max)180°F / 82°C
Best for

Use cases.

  • Airport terminal complexes requiring simultaneous concourse cooling and service-water heating
  • District energy schemes where recovered condenser heat replaces gas or steam boiler output
  • Hotels and mixed-use developments with large domestic hot-water demand alongside comfort cooling
  • Pharmaceutical and food-processing facilities requiring high-grade process heat plus chilled water
  • Decarbonisation projects replacing gas boiler plant in existing buildings served by chilled-water infrastructure
  • High-density commercial campuses seeking single-system thermal management instead of dual mechanical plant