APSG VFD Air-Cooled Variable-Speed Screw Chiller
Variable-speed air-cooled screw chiller with R-1234ze refrigerant and IPLV up to 5.85 kW/kW, engineered for large commercial plants where part-load efficiency and low ambient noise are non-negotiable.
The APSG VFD is Petra Engineering's flagship air-cooled chiller, combining a semi-hermetic twin-screw compressor with an integrated variable frequency drive to deliver cooling capacity that tracks actual building load rather than running flat-out against a fixed setpoint. The VFD continuously trims compressor speed, producing part-load efficiency (IPLV) of up to 5.85 kW/kW in the high-efficiency variant — a 20–25% improvement over fixed-speed screw equivalents running the same annual duty profile.
This chiller suits large commercial and institutional plants: convention centres, hospital complexes, large terminal buildings, and district-cooling satellite plants where chillers spend the majority of their hours at 40–70% load. The microchannel condenser coil (MCHE) design reduces refrigerant charge and condenser footprint while maintaining heat-rejection capacity at elevated ambient temperatures, a critical trait for GCC rooftop installations where design dry-bulb can exceed 46 °C. Refrigerant R-1234ze carries a GWP of just 7, meeting current and anticipated low-GWP regulatory thresholds without compromising capacity.
Soft-start is standard, eliminating the high-inrush current demand penalty on generator-backed or constrained utility feeds — relevant for sites where standby power is sized to a strict kVA budget. Optional cooler tape heaters rated to −29 °C extend deployability to cold-climate satellite facilities. The unit is AHRI 550/590 and Eurovent certified, giving specifying engineers third-party verified capacity and efficiency data rather than manufacturer-declared figures. Electrical panels meet NEMA 3X / IP54 as standard, with NEMA 4X stainless steel available for coastal or corrosive-atmosphere sites.
Technical specifications.
| IPLV (high-efficiency) | 5.85 kW/kW |
| Part-load improvement vs fixed-speed | 20–25 % |
| Refrigerant | R-1234ze (GWP 7) |
| Compressor type | Semi-hermetic twin screw, VFD-driven |
| Condenser coil | Microchannel (MCHE) |
| Refrigerant-side design pressure | 1,000 kPa |
| Water-side max working pressure | 1,500 kPa |
| Electrical panel rating (standard) | NEMA 3X / IP54 |
| Low-ambient heater protection (optional) | Down to −29 °C |
| Efficiency standard compliance | ASHRAE 90.1 |
| Certification | AHRI 550/590, Eurovent |
Use cases.
- ›Central chilled-water plants serving large terminal buildings, convention centres, or hotel complexes requiring verified part-load efficiency
- ›GCC rooftop chiller installations where high ambient dry-bulb and low-GWP refrigerant mandates apply simultaneously
- ›Generator-backed or constrained-utility sites benefiting from soft-start to limit inrush kVA demand
- ›Noise-sensitive environments (hospitals, residential-adjacent facilities) where low-RPM fan and compressor sound-attenuation options are specified
- ›Retrofit replacements for ageing fixed-speed screw plant where energy cost reduction underpins the business case
- ›District-cooling satellite plants requiring AHRI/Eurovent third-party certified capacity data for contractual performance guarantees